Electrical Operated Valve Sensor
Add Product to FavoritesProduct Details:
| Model Number | SD-10/K25H |
|---|
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 Set/Sets 1 set |
|---|---|
| Price: | FOB USD 1~99999 |
| Port: | Tianjin |
| Packaging Details: | wooden packing |
| Delivery Time: | 7-30 working days |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 9999 Set/Sets per Year |
Detailed Product Description
Electrical Operated Valve Sensor :
| Rated torque | Travel time | Ball hinge type | ||||||
SH-10/K25H | 100 | 25 | SQJ-10 | ||||||
SH-10/F25H | 100 | 25 | SQJ-10 | ||||||
SH- |
|
|
|
|
|
| Code | ||
|
| / |
|
|
|
| The maximum output torque, numbers that, unit: Nm | ||
| K |
|
|
| Power codesignal phase220V/50Hz | ||||
F |
|
|
| Power code3- phase 380V/50Hz | |||||
|
|
|
| Rated travel time, number of that unit; S | |||||
| H |
| Installation Type | Base type | |||||
Z |
| Direct-coupled type | |||||||
| L | Control Characteristics | 2 Type | ||||||
Unsigned | The overall proportion of type 4-20mA | ||||||||
S | Discrete proportional 4-20mA | ||||||||
Y | Remote control-type | ||||||||
Main Technical Performance:
The following technical performance mainly refers to the proportion of adjustable type, on the far-controlled and the switching of the following 1,2,3,4,5,6,11,12,13,14 are not concern.
1, input signal: 4mA-20mA DC or 1V-5V DC;
2, enter the channel resistance; 250Ω;
3, input channel number: 1 (discrete formula 3);
4, the basic error: ± 1, ± 2.5%;
5, hysteresis: 1%, 1.5%;
6, dead-0.5-3% (can be set according to system requirements);
7, damping properties: no swing
8, power supply voltage: single phase 220V (+10%, -15%) 50Hz ± 1%
Three-phase 380V ± 10% 50Hz ± 1%
9, the working environment: temperature: Integral -10 - +55 ; discrete -25 - +70 ;
Humidity: ≤ 85%, ambient air does not contain corrosive substances;
10, shell protection grade; meet GB4208 IP65 (dust or rain);
11, broken signal protection functions: preset There are three ways: a, in situ, b, fully open,
c, all closed;
12, over-current protection function: pairs of different types of models, to protect current value adjustable; (mechanical parts there have been moments Protection Switch)
13, the dynamic electrical braking function;
14, the ceiling and the lower limit function: at rated travel within the range of upper and lower limits adjustable
In about 40%; (mechanical parts of a stroke control switches and mechanical limit)
15, the working system; reversible intermittent working system, connected to sustained rate of 50% per hour connect time
The number of 1200 times.
Electrical Operated Valve Sensor
Other Products from this Supplier
See more
Electrical Operated Valve Sensor, Electrical equipment, valve actuators products from this supplier.